SELFOC® Imaging Lens

Advantages:

[Bullet] Small Diameter
[Bullet] Stable Cylindrical Shape
[Bullet] Simplified Mounting

The SELFOC® Imaging lens is commonly used as an objective lens for small diameter imaging systems where conventional lenses are not suitable due to size limitation. The lens is designed to gather light from an object and form an inverted image at the back surface of the lens. Typical applications include fiberscope (attached to a coherent fiber bundle) and rigid endoscope (attached to a relay lens such as a SELFOC® Rod Lens, see next section).

SELFOC Imaging Lenses are specified somewhat differently that SELFOC MicroLenses (SML). While SML performance is controlled through the lens pitch and gradient constant (ÖA), Imaging Lens performance is controlled via the working distance (WD) and image quality factors such as resolution and field curvature. For this reason, ILW and ILH lenses can consistently exhibit good image quality despite variations in ÖA and/or Z (Lens Length).

Proper handling and storage of lenses.

Table 2 Specifications

Lens Type
& Dia.(mm)

Lens Length

Z (mm)

Resolution (LP/mm)

Typ.
Chromatic
Aberration
(
mm)

Typical

ÖA (mm-1)

(Magnif.)-1
at WD=5 mm

Field

Curvature

(m m)

View Angle

(2q)

Refractive

Index (N0)

Center

@ 0.8R

ILW-0.25

0.70 +/- 0.10

400

150

---

2.319

19.1

40

50°

min.

1.643

on axis

ILW-0.35

0.96 +/- 0.10

300

120

49

1.710

14.1

40

ILW-0.50

1.39 +/- 0.13

250

100

51

1.203

9.9

50

ILW-0.70

2.00 +/- 0.20

200

80

82

0.856

7.1

60

ILW-1.00

2.95 +/- 0.30

200

50

102

0.600

5.1

80

ILW-1.30

3.96 +/- 0.35

180

40

144

0.462

3.9

100

ILW-2.00

6.54 +/- 0.60

160

30

261

0.299

2.7

150

ILW-2.70

9.34 +/- 0.80

140

20

314

0.222

2.1

200

ILH-0.25

0.50 +/- 0.10

400

150

---

3.126

26.9

40

70°

min.

1.666

on axis

ILH-0.35

0.74 +/- 0.10

350

120

35

2.196

18.4

60

ILH-0.50

1.05 +/- 0.15

300

80

42

1.569

13.1

80

ILH-0.70

1.50 +/- 0.20

280

60

47

1.118

9.4

100

ILH-1.00

2.19 +/- 0.30

250

30

76

0.786

6.7

100

Specification Notes:
[Bullet] Standard working distance is 5 mm for all ILW and ILH.
[Bullet] Diameter tolerance is +0/-0.05 mm for all ILW and ILH.
[Bullet] Resolution is measured on a U.S. Air Force chart while a 100X microscope is focused on the back surface of the imaging lens (see Figure). The chart is placed at 5 mm, the standard working distance, away from the lens. Resolution is measured at both lens center and 80% of the lens radius and normalized by the magnification factor.
[Bullet] Field curvature is the difference in focal positions between the lens center and at 80% of the lens radius.
[Bullet] End surface is inspected at 20X magnification. No chips and cracks are allowed within 90% of the lens radius.
[Bullet] Material Toxicity: This product contains components which might be toxic. The user is advised to pay special attention to such toxicity when using this product in medical devices for people or animals.
[Bullet] Hand-held copier
[Bullet] Storage and Handling.

 

Ordering Information

Example:

Type

Diameter

Pitch

Wavelength

AR Coating;
Metallization

ILW

025

W05

055

C1M

AR Coating: NC = Non-coated; C1, C2 (for diameter ³ 0.7 mm only, 50 pieces minimum)

Metallization: M = Metallization, 0 = Non-metallized (or diameter ³ 0.7 mm only, 100 pieces minimum)

 

 

NSG EUROPE • Advanced Materials and Applications Division • Krijgsbaan 247 • 9140 Temse • Belgium
Tel: +32 (0)3-711.10.09   Fax: +32 (0)3-711.15.34 • E-mail: ama@nsgeurope.be